Mechanotransmission of haemodynamic forces by the endothelial glycocalyx in a full-scale arterial model

Author (s): Sáez P.; Gallo, D.; Morbiducci, U.
Journal: Royal Society Open Science

Volume: 6
Date: 2019

Abstract:
The glycocalyx has been identified as a key mechano-sensor of the shear forces exerted by streaming blood onto the vascular endothelial lining. Although the biochemical reaction to the blood flow has been extensively studied, the mechanism of transmission of the haemodynamic shear forces to the endothelial transmembrane anchoring structures and, consequently, to the subcellular elements in the cytoskeleton, is still not fully understood. Here we apply a multiscale approach to elucidate how haemodynamic shear forces are transmitted to the transmembrane anchors of endothelial cells. Wall shear stress time histories, as obtained from image-based computational haemodynamics models of a carotid bifurcation, are used as a load and a continuum model is applied to obtain the mechanical response of the glycocalyx all along the cardiac cycle. The main findings of this in silico study are that: (1) the forces transmitted to the transmembrane anchors are in the range of 1-10 pN, which is in the order of magnitude reported for the different conformational states of transmembrane mechanotranductors; (2) locally, the forces transmitted to the anchors of the glycocalyx structure can be markedly different from the near-wall haemodynamic shear forces both in amplitude and frequency content. The findings of this in silico approach warrant future studies focusing on the actual forces transmitted to the transmembrane mechanotransductors, which might outperform haemodynamic descriptors of disturbed shear as localizing factors of vascular disease.

  
  

Bibtex:








@article{doi:10.1098/rsos.190607,
author = {Saez, P.  and Gallo, D.  and Morbiducci, U. },
title = {Mechanotransmission of haemodynamic forces by the endothelial glycocalyx in a full-scale arterial model},
journal = {Royal Society Open Science},
volume = {6},
number = {6},
pages = {190607},
year = {2019},
doi = {10.1098/rsos.190607},

URL = {https://royalsocietypublishing.org/doi/abs/10.1098/rsos.190607},
eprint = {https://royalsocietypublishing.org/doi/pdf/10.1098/rsos.190607}
,
    abstract = { The glycocalyx has been identified as a key mechano-sensor of the shear forces exerted by streaming blood onto the vascular endothelial lining. Although the biochemical reaction to the blood flow has been extensively studied, the mechanism of transmission of the haemodynamic shear forces to the endothelial transmembrane anchoring structures and, consequently, to the subcellular elements in the cytoskeleton, is still not fully understood. Here we apply a multiscale approach to elucidate how haemodynamic shear forces are transmitted to the transmembrane anchors of endothelial cells. Wall shear stress time histories, as obtained from image-based computational haemodynamics models of a carotid bifurcation, are used as a load and a continuum model is applied to obtain the mechanical response of the glycocalyx all along the cardiac cycle. The main findings of this in silico study are that: (1) the forces transmitted to the transmembrane anchors are in the range of 1–10 pN, which is in the order of magnitude reported for the different conformational states of transmembrane mechanotranductors; (2) locally, the forces transmitted to the anchors of the glycocalyx structure can be markedly different from the near-wall haemodynamic shear forces both in amplitude and frequency content. The findings of this in silico approach warrant future studies focusing on the actual forces transmitted to the transmembrane mechanotransductors, which might outperform haemodynamic descriptors of disturbed shear as localizing factors of vascular disease. }
}